Page 83 - Industrial Plants
P. 83

RO rack arrangement
                                                                                               SALALAH IWP
                                                                                               (Fisia Italimpianti &
                                                                                               Abengoa)


            The seawater quality and the effluent discharge have
            been considered in the design and dimensioning of the
            desalination plant, with the aim of complying with the
            technical and operational expectations and
            requirements. In summary, the design criteria aim to
            achieve the following objectives:
            •   Ensure the guaranteed water capacity, availability
                and quality as required, maximizing the availability
                of the plant and it components.
            •   Optimize the energy consumption; in order to
                minimize the cost per cubic meter of desalted
                water.
            •   Design the plant in a comprehensive approach
                which considers the operation and maintenance
                period and the whole life of the project, minimizing
                operation and maintenance costs.
            •   Optimize the quality of the installed equipment
                with the best and most reliable suppliers and   The scope of the Project includes the engineering,   Dissolved Air
                technologies, paying special attention in reducing   procurement, construction and startup of a desalination   Flotation system
                the noise and vibrations levels.      facilities based on seawater reverse osmosis   SALALAH IWP
            •   Optimize the layout of the plant to ensure a proper   technology.               (Fisia Italimpianti &
                                                                                               Abengoa)
                accessibility to equipment for a correct operation   As brief summary of the processes and equipment
                and maintenance, considering the topographical   included within the scope is listed hereinafter:
                and geotechnical characteristics of the site and   •   Intake system, comprising the Intake basin along
                the logical sequence of the treatment    with the screening channels and the seawater
            •   Ensure the maximum flexibility in operation by   feed pumps, the raw water intake pipeline, the
                implementing optimal automation processes;  Intake risers (towers) and the disinfection system
            •   Minimize the environmental and visual impact   for at the intake risers and the intake basin.
                during plant execution and operation in order to   •   Pre-treatment  system, comprising  the  DAF
                fully integrate them in the site.        system, the multimedia gravity filters, the
            •   Maximize the safety of the plant operation.  multimedia pressurized filters and the required
                                                         coagulant and flocculant dosing system.