maximum practical and feasible size. Then, a further
                             expansion was obtained by adding a third cell  Conclusions
                             equipped with three fans. Finally, the use of ultra low   A strict co-operation was established between
                             noise fans (swirled blades fans) in place of low noise   Boldrocchi and Renco to optimize the design of the air
                             fans (straight blades fans) allowed the meeting of   cooled heat exchangers for a gas compressor station in
                             the projects needs in terms of noise.    Denmark.
                             It is interesting to note how the reduction of noise   “Renco was awarded the contract
                             emission was obtained together with the reduction   in May 2020 and Boldrocchi fully
                             of  the  electric  power  consumption.  This  was   delivered the equipment in May 2021
                             basically  due to  the reduction of  ambient air flow
                             needed for cooling, hence the reduction of fans   The possibility of discussing the project since the very
                             load, and not because of the different efficiency   beginning allowed the needed degree of freedom for
                             levels of fans. Low noise fans are indeed usually less   finding the right compromise between performance and
                             efficient than regular fans.             cost, and allowed to win the Project. Renco was
                             Other expediencies have been applied and taken   awarded in May 2020 and Boldrocchi fully delivered the
                             into account to reduce noise but are not reported   equipment in may 2021. The project has been
                             here as related contribution to noise reduction is   challenging for all people involved but has brought great
                             limited.                                 satisfaction.














                             Marco Soffi ato



                             Passionate about noise, energy, and techno-economic   sector for 8 years. Sales Engineer at Boldrocchi’s for the
                             optimizations. He holds a master degree in energy   Air Cooled Heat Exchangers.
                             engineering and have worked in the power generation







                             Nicola Mauri


                             Sales Manager at Boldrocchi’s for the Air Cooled Heat   and power generation applications, developing solutions
                             exchangers.  He  joined  the  Company  in  2006  and   for non-standard applications.
                             worked on several projects for the Oil&Gas, industrial




                             Stefano Vaccarini



                             Machinery & Package Engineer in the Industrial Plants   Specialist Leader for mechanical discipline, including
                             Division of Renco S.p.A. since 2016. Followed the   noise performance management for equipment and the
                             supplies of machineries, packages and static equipment   entire Plants.
                             for  several compression stations.  Currently Project